Show simple item record

dc.contributor.authorTobin, M.
dc.contributor.authorVongsvivut, J.
dc.contributor.authorMartin, D.
dc.contributor.authorSizeland, K.
dc.contributor.authorHackett, Mark
dc.contributor.authorTakechi, Ryu
dc.contributor.authorFimorgnari, N.
dc.contributor.authorLam, Virginie
dc.contributor.authorMamo, John
dc.contributor.authorCarter, E.
dc.contributor.authorSwarbrick, B.
dc.contributor.authorLay, P.
dc.contributor.authorChristensen, D.
dc.contributor.authorPerez-Guaita, D.
dc.contributor.authorLowery, E.
dc.contributor.authorHeraud, P.
dc.contributor.authorWood, B.
dc.contributor.authorPuskar, L.
dc.contributor.authorBambery, K.
dc.date.accessioned2018-12-13T09:10:40Z
dc.date.available2018-12-13T09:10:40Z
dc.date.created2018-12-12T02:47:03Z
dc.date.issued2018
dc.identifier.citationTobin, M. and Vongsvivut, J. and Martin, D. and Sizeland, K. and Hackett, M. and Takechi, R. and Fimorgnari, N. et al. 2018. Focal plane array IR imaging at the Australian Synchrotron. Infrared Physics and Technology. 94: pp. 85-90.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/71588
dc.identifier.doi10.1016/j.infrared.2018.06.022
dc.description.abstract

© 2018 A Focal Plane Array FTIR microscope has successfully been coupled to the IRM beamline at the Australian Synchrotron, following the method pioneered at previous beamlines at the SRC and NSLS I synchrotrons, whereby a wide aperture of synchrotron light is split into multiple beams and spatially reconfigured to match the entrance aperture of the FTIR instrumentation. Imaging performance has been assessed using a selection of polymer and biological samples, providing diffraction-limited sub-cellular lateral resolution in the biological materials. We have demonstrated that improved collection times at high lateral resolution are possible, when compared with single element point-mapping microspectroscopy, though this is achieved with a trade off in spectral noise. Future improvements in the use of an FPA detector at the Australian Synchrotron are proposed, including removal of coherent interference and installation of a dedicated beam extraction port for FPA microspectroscopy.

dc.titleFocal plane array IR imaging at the Australian Synchrotron
dc.typeJournal Article
dcterms.source.volume94
dcterms.source.startPage85
dcterms.source.endPage90
dcterms.source.issn1350-4495
dcterms.source.titleInfrared Physics and Technology
curtin.departmentSchool of Molecular and Life Sciences (MLS)
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record