Comparison of the Performance of Computed Radiography and Direct Radiography in Glass Soft Tissue Foreign Body Visualisation
Access Status
Authors
Date
2018Type
Metadata
Show full item recordCitation
Source Title
ISSN
School
Collection
Abstract
Purpose: The purpose of the study was to investigate the performance of recent computed radiography (CR) and direct radiography (DR) in glass soft tissue foreign body (FB) visualisation in terms of their overall performance, and effects of sizes and locations of FB, and exposure parameters on the visualisation. Methods: Eighty anteroposterior (AP) and 80 lateral images of chicken legs with five sizes of FBs inserted into two locations were taken by our CR and DR systems using four exposure parameter combinations. Contrast-to-noise ratio (CNR), and visual grading analysis (VGA), were employed to assess the FB visibility. The CNR and VGA data were analysed using descriptive and inferential statistics. Results: The mean CNR value, 3.89 and median VGA score, 1 (definitely invisible) of all CR images were statistically significantly lower than the mean CNR value, 9.47 (p<0.001) and median VGA score, 2 (possible visible [but uncertain]) of all DR images (p<0.05) respectively. Despite this, the FBs were visible on CR (median VGA score: 3 - visible but could be shown better) and DR (median VGA score: 4 - definitely visible) lateral images (without FBs overlapping with bone). The smallest FBs visible on CR and DR lateral images were 2 and 1 mm respectively. The factors of FB depths and kV settings did not have any statistically significant effects on FB visibility (p>0.05). Conclusion: The performance of recent DR system in glass soft tissue FB visualisation appears more superior to CR. DR should be used to take orthogonal (AP and lateral) images for detecting any small FBs.
Related items
Showing items related by title, author, creator and subject.
-
Kleinfelder, Thomas R; Ng, Curtise (2022)Purpose: To investigate the effects of image postprocessing functions (ie, edge enhancement, noise reduction, and sharpening) that are available on digital radiography systems, including computed radiography (CR) and ...
-
Sun, Zhonghua; Siddiqu, Salim; Ng, K.; Ramli, K.; Davidson, R. (2007)Objective: Digital imaging is gradually replacing the conventional film-screen (FS) imaging technology. This is mainly due to the perceived advantages of digital image processing, electronic archiving, teleradiology and ...
-
Sun, Zhonghua (2014)This study was performed on an anthropomorphic phantom to investigate the performance of three computed radiography (CR) systems with regard to the detection of simulated lung nodules and entrance skin dose. Forty-five ...