Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate
dc.contributor.author | Liang, J. | |
dc.contributor.author | Sun, Y. | |
dc.contributor.author | Ye, Z. | |
dc.contributor.author | Sun, Y. | |
dc.contributor.author | Xu, L. | |
dc.contributor.author | Zhou, Z. | |
dc.contributor.author | Thomsen, B. | |
dc.contributor.author | Li, J. | |
dc.contributor.author | Sun, Zhonghua | |
dc.contributor.author | Fan, Z. | |
dc.date.accessioned | 2019-02-19T04:14:45Z | |
dc.date.available | 2019-02-19T04:14:45Z | |
dc.date.created | 2019-02-19T03:58:25Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Liang, J. and Sun, Y. and Ye, Z. and Sun, Y. and Xu, L. and Zhou, Z. and Thomsen, B. et al. 2019. Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate. European Radiology. 29 (8): pp. 4215–4227. | |
dc.identifier.uri | http://hdl.handle.net/20.500.11937/73799 | |
dc.identifier.doi | 10.1007/s00330-018-5929-6 | |
dc.description.abstract |
Objective: To assess the effect of a second-generation motion correction algorithm on the diagnostic accuracy of coronary computed tomography angiography (CCTA) using a 256-detector row CT in patients with increased heart rates. Methods: Eighty-one consecutive symptomatic cardiac patients with increased heart rates (= 75 beats per min) were enrolled. All patients underwent CCTA and invasive coronary angiography (ICA). CCTA was performed with a 256-detector row CT using prospectively ECG-triggered single-beat protocol. Images were reconstructed using standard (STD) algorithm, first-generation intra-cycle motion correction (MC1) algorithm, and second-generation intra-cycle motion correction (MC2) algorithm. The image quality of coronary artery segments was assessed by two experienced radiologists using a 4-point scale (1: non-diagnostic and 4: excellent), according to the 18-segment model. Diagnostic performance for segments with significant lumen stenosis (= 50%) was compared between STD, MC1, and MC2 by using ICA as the reference standard. Results: The mean effective dose of CCTA was 1.0 mSv. On per-segment level, the overall image quality score and interpretability were improved to 3.56 ± 0.63 and 99.2% due to the use of MC2, as compared to 2.81 ± 0.85 and 92.5% with STD and 3.21 ± 0.79 and 97.2% with MC1. On per-segment level, compared to STD and MC1, MC2 improved the sensitivity (92.2% vs. 79.2%, 80.7%), specificity (97.8% vs. 82.1%, 90.8%), positive predictive value (89.9% vs. 48.4%, 65.1%), negative predictive value (98.3% vs. 94.9%, 95.7%), and diagnostic accuracy (96.8% vs. 81.5%, 89.0%). Conclusion: A second-generation intra-cycle motion correction algorithm for single-beat CCTA significantly improves image quality and diagnostic accuracy in patients with increased heart rate. Key Points: • A second-generation motion correction (MC2) algorithm can further improve the image quality of all coronary arteries than a first-generation motion correction (MC1). • MC2 algorithm can significantly reduce the number of false positive segments compared to standard and MC1 algorithm. | |
dc.title | Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate | |
dc.type | Journal Article | |
dcterms.source.issn | 0938-7994 | |
dcterms.source.title | European Radiology | |
curtin.department | School of Molecular and Life Sciences (MLS) | |
curtin.accessStatus | Fulltext not available |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |