Effective dose and image optimisation of lateral lumbar spine radiography: a phantom study
Citation
Source Title
Faculty
School
Collection
Abstract
Background: To investigate lateral lumbar spine radiography technical parameters for reduction of effective dose whilst maintaining image quality (IQ). Methods: Thirty-six radiograms of an anthropomorphic phantom were acquired using different exposure parameters: source-to-detector distance (SDD) (100, 130 or 150 cm), tube potential (75, 85 or 95 kVp), tube current × exposure time product (4.5, 9, 18 mAs) and additional copper (Cu) filter (no filter, 0.1-, 0.2-, or 0.3-mm thickness. IQ was assessed using an objective approach (contrast-to-noise-ratio [CNR] calculation and magnification measurement) and a perceptual approach (six observers); ED was estimated using the PCXMC 2.0 software. Descriptive statistics, paired t test, and intraclass correlation coefficient (ICC) were used. Results: The highest ED (0.022 mSv) was found with 100 cm SSD, 75 kVp, 18 mAs, and without Cu filter, whilst the highest CNR (7.23) was achieved at 130 cm SSD, 75 kVp, 18 mAs, and without Cu filter. The lowest ED and CNR were generated at 150 cm SDD, 95 kVp, 4.5 mAs, and 0.3-mm Cu filter. All observers identified the relevant anatomical structures on all images with the lowest ED and IQ. The intra-observer (0.61–0.79) and inter-observer (0.55–0.82) ICC ranged from moderate to excellent. Conclusion: All relevant anatomical structures were identified on the lateral lumbar spine radiographs despite using low-dose protocols. The lowest ED (0.002 mSv) was obtained with 150 cm SDD, 95 kVp, 4.5 mAs, and 0.3-mm Cu filter. Further technical and clinical studies are needed to verify these preliminary findings
Showing items related by title, author, creator and subject.
-
Tseng, Chien H. (1999)The design of envelope-constrained (EC) filters is considered for the time-domain synthesis of filters for signal processing problems. The objective is to achieve minimal noise enhancement where the shape of the filter ...
-
Mullins, Ben; Mead-Hunter, Ryan; Pitta, R.; Kasper, G.; Heikamp, W. (2014)The evolution of pressure drop, drainage rate, saturation, and efficiency of combined philic, and phobic oil mist filters in real-time are examined. The experiments used four different filter configurations, with a ...
-
Alsaaq, Faisal; Kuhn, Michael; El-Mowafy, Ahmed ; Kennedy, Paul (2016)Hydrographic surveys have traditionally relied on the availability of tide information for the reduction of sounding observations to a common (chart) datum usually related to a specific tide level. In most cases, tide ...