dc.description.abstract

Over the past several decades, iconic and public buildings have become targets of terrorist bomb attacks, but most of these buildings were built without consideration of blast loading scenarios. Key load-carrying elements such as concrete columns are probably the most critical structural components for structural protection against bomb threats. Failures of columns may trigger catastrophic progressive collapse if there is insufficient structural redundancy. In a recent study, novel ultra-high performance concrete (UHPC) material formulated based on reactive powder concrete (RPC) was developed. Field blast tests on columns made of this material were performed. Test results showed that UHPC columns had excellent blast resistant capability, only small mid-height deflection and minor concrete damage was observed after the blasting tests. In the present study, to quantify blast-induced damage and assess residual loading capacity of UHPC columns, static axial loading tests on post-blast UHPC columns were carried out. Undamaged control samples were tested to provide benchmarks. Damage index and residual loading capacity of UHPC columns after various blast loadings were obtained. It was found that column cast with micro steel fibre reinforced UHPC preserved more than 70% of its loading capacity after 35 kg TNT detonation at 1.5 m standoff distance, while high strength concrete column only maintained 40% loading capacity after 8 kg TNT detonation at 1.5 m standoff distance.

dc.publisherPergamon
dc.titlePost-blast capacity of ultra-high performance concrete columns
dc.typeJournal Article
dcterms.source.volume134
dcterms.source.startPage289
dcterms.source.endPage302
dcterms.source.issn0141-0296
dcterms.source.titleEngineering Structures
curtin.departmentDepartment of Civil Engineering
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record