Myocardial extracellular volume fraction quantification in an animal model of the doxorubicin-induced myocardial fibrosis: a synthetic hematocrit method using 3T cardiac magnetic resonance
Citation
Source Title
Additional URLs
ISSN
Faculty
School
Collection
Abstract
Background: Visualization of diffuse myocardial fibrosis is challenging and mainly relies on histology. Cardiac magnetic resonance (CMR), which uses extracellular contrast agents, is a rapidly developing technique for measuring the extracellular volume (ECV). The objective of this study was to evaluate the feasibility of the synthetic myocardial ECV fraction based on 3.0 T CMR compared with the conventional ECV fraction. Methods: This study was approved by the local animal care and ethics committee. Fifteen beagle models with diffuse myocardial fibrosis, including 12 experimental and three control subjects, were generated by injecting doxorubicin 30 mg/m2 intravenously every three weeks for 24 weeks. Short-axis (SAX) and 4-chamber long-axis (LAX) T1 maps were acquired for both groups. The association between hematocrit (Hct) and native T1blood was derived from 9 non-contrast CMR T1 maps of 3 control beagles using regression analysis. Synthetic ECV was then calculated using the synthetic Hct and compared with conventional ECV at baseline and the 16th and 24th week after doxorubicin administration. The collagen volume fraction (CVF) value was measured on digital biopsy samples. Bland-Altman plots were used to analyze the agreement between conventional and synthetic ECV. Correlation analyses were performed to explore the association among conventional ECV, synthetic ECV, CVF, and left ventricular ejection fraction (LVEF). Results: The regression model synthetic Hct = 816.46*R1blood − 0.01 (R2=0.617; P=0.012) was used to predict the Hct from native T1blood values. The conventional and synthetic ECV fractions of experimental animals at the 16th and 24th week after modeling were significantly higher than those measured at the baseline (31.4%±2.2% and 36.3%±2.1% vs. 22.9%±1.7%; 29.9%±2.4% and 36.1%±2.6% vs. 22.0%±2.4%; all with P<0.05). Bland-Altman plots showed a bias (1.0%) between conventional and synthetic ECV with 95% limits of agreement of −2.5% to 4.4% in the per-subject analysis (n=21) and a bias (1.0%) between conventional and synthetic ECV with 95% limits of agreement of −2.4% to 4.3% in the per-segment analysis (n=294). Conventional and synthetic ECV were well correlated with CVF (r=0.937 and 0.925, all with P<0.001, n=10). Conclusions: Our study showed promising results for using synthetic ECV compared with the conventional ECV for providing accurate quantification of myocardial ECV without the need for blood sampling.
Related items
Showing items related by title, author, creator and subject.
-
Zhou, Z.; Gao, Y.; Wang, H.; Wang, W.; Zhang, H.; Wang, S.; Sun, Zhonghua ; Xu, L. (2021)Background: Dual-energy CT (DECT) permits the simultaneous operation of two different kV levels, providing a potential method toward the assessment of diffuse myocardial fibrosis. The purpose of this study was to determine ...
-
Allpike, Bradley (2008)Natural organic matter (NOM), ubiquitous in natural water sources, is generated by biogeochemical processes in both the water body and in the surrounding watershed, as well as from the contribution of organic compounds ...
-
Zhou, Z.; Xu, L.; Wang, R.; Varga-Szemes, A.; Durden, J.; Joseph Schoepf, U.; Fan, Z.; Sun, Zhonghua (2019)Background: The noninvasive equilibrium contrast-enhanced cardiac computed tomography(CCT) has potential for myocardial tissue characterization. The objective of this study was to test the feasibility of CCT-based ...