Impact of Load Ramping on Power Transformer Dissolved Gas Analysis
Citation
Source Title
ISSN
Faculty
School
Collection
Abstract
Dissolved gas in oil analysis (DGA) is one of the most reliable condition monitoring techniques, which is currently used by the industry to detect incipient faults within the power transformers. While the technique is well matured since the development of various offline and online measurement techniques along with various interpretation methods, no much attention was given so far to the oil sampling time and its correlation with the transformer loading. A power transformer loading is subject to continuous daily and seasonal variations, which is expected to increase with the increased penetration level of renewable energy sources of intermittent characteristics, such as photovoltaic (PV) and wind energy into the current electricity grids. Generating unit transformers also undergoes similar loading variations to follow the demand, particularly in the new electricity market. As such, the insulation system within the power transformers is expected to exhibit operating temperature variations due to the continuous ramping up and down of the generation and load. If the oil is sampled for the DGA measurement during such ramping cycles, results will not be accurate, and a fault may be reported due to a gas evolution resulting from such temporarily loading variation. This paper is aimed at correlating the generation and load ramping with the DGA measurements through extensive experimental analyses. The results reveal a strong correlation between the sampling time and the generation/load ramping. The experimental results show the effect of load variations on the gas generation and demonstrate the vulnerabilities of misinterpretation of transformer faults resulting from temporary gas evolution. To achieve accurate DGA, transformer loading profile during oil sampling for the DGA measurement should be available. Based on the initial investigation in this paper, the more accurate DGA results can be achieved after a ramping down cycle of the load. This sampling time could be defined as an optimum oil sampling time for transformer DGA.
Related items
Showing items related by title, author, creator and subject.
-
Kamiel, B.; Howard, Ian (2014)Centrifugal pumps are one of the rotating machines that are widely used in various industries such as oil and gas, petrochemical, water treatment, power generation, agriculture, and fertilizers. During its operation, it ...
-
Bakar, N.; Abu-Siada, Ahmed; Cui, H.; Li, S. (2017)© 2017 IEEE. Dissolved gas analysis (DGA) is the most effective method to detect incipient faults in power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition ...
-
Abu Bakar, Norazhar; Abu-Siada, Ahmed (2017)Dissolved gas analysis (DGA) is widely accepted as an effective technique to detect incipient faults within power transformers. Gases such as hydrogen, methane, acetylene, ethylene and ethane are generated as a result of ...