Targeted defect analysis in VCSEL oxide windows using 3D slice and view
Access Status
Authors
Date
2021Type
Metadata
Show full item recordCitation
Source Title
ISSN
Faculty
School
Collection
Abstract
We report on high resolution analysis of vertical cavity surface emitting lasers (VCSELs) to detect and assess defects in sub-surface layers. We employ a focussed ion beam scanning electron microscope (FIB-SEM) to sputter and image successive cross sections (slice and view technique) in order to produce a 3D reconstruction of the oxide aperture region. High resolution images and measurements of the multilayers and oxide apertures of VCSEL devices were obtained. The process took ∼2.5 h and produced over 270 slice SEM images for a device volume of approximately 13.2 × 16.0 × 13.8 μm3, with a voxel size of 50 nm. On-wafer, single mode VCSEL devices with high and low output powers were analysed to compare their oxide apertures and distributed Bragg reflector (DBR) layer structures. It was found that the low output power VCSEL had DBR layer defects and a 41.8% reduction of effective oxide aperture area, explaining the lower power obtained. The results provide evidence that oxide aperture area and structural defects are major factors that affect the optical output power of VCSEL devices. Outcomes in this work show FIB-SEM slice and view is a valuable method for 3D reconstruction of VCSEL devices, which enables top view, cross-sectional view and angled view of the whole device region as well as designated structures such as oxide aperture or structural defects in various layers. This work demonstrates a promising technique with high resolution (50 nm) 3D imaging for analysis of complex semiconductor devices.
Related items
Showing items related by title, author, creator and subject.
-
Mahmud, M.; Elumalai, Naveen Kumar; Upama, M.; Wang, D.; Soufiani, A.; Wright, M.; Xu, C.; Haque, F.; Uddin, A. (2017)The current work reports the lithium (Li) doping of a low-temperature processed zinc oxide (ZnO) electron transport layer (ETL) for highly efficient, triple-cation-based MA0.57FA0.38Rb0.05PbI3 (MA: methylammonium, FA: ...
-
Sabarudin, Akmal (2012)Prospective ECG-triggering is regarded as one of the most effective approaches for reduction of radiation dose to patients during coronary CT angiography (CCTA). This study was conducted to investigate the diagnostic ...
-
Shiyab, Adnan M S H (2007)This study aimed at investigating the current practices and methods adopted by roads agencies around the world with regard to collection, analysis and utilization of the data elements pertaining to the main pavement ...