Factors influencing impact force profile and measurement accuracy in drop weight impact tests
Citation
Source Title
ISSN
Faculty
School
Funding and Sponsorship
Collection
Abstract
Drop weight tests on RC beams have been intensively reported in literature. Load cells are commonly used to measure the impact force acting on the beam. Different researchers adopted different configurations, e.g., location of load cells in the test, which could affect the impact load measurement. Although various impact force profiles have been reported by different researchers, there is no systematic study regarding the influences of the test setup on the measured impact forces. Therefore, this study numerically investigates the influences of test setups on impact force measurement accuracy and impact force profile of RC beam under drop weight impact. It is found that when the load cell is embedded into drop weight, the mass distribution of drop weight causes the measured impact force to deviate from the actual contact force acting on the beam. To obtain the true impact force recorded by the load cell mounted at the rear of drop weight head, the drop weight mass ratio αd (i.e., mass of the drop-weight to mass of the head) should be lower than 20. Placing load cell between drop weight and beam changes the local contact stiffness of impact zone and thus leads to different impact force profiles. In addition, the drop weight to beam mass ratio within the range of 0.5 and 4.0 affects the relative velocity between drop weight and beam after the first impulse and hence results in different impact force profiles.
Related items
Showing items related by title, author, creator and subject.
-
Hao, Hong ; Tran, Tung ; Li, Huawei; Pham, Thong ; Chen, Wensu (2021)The impact response of reinforced concrete (RC) beams has been intensively investigated by impact tests with various setups. Given the same impact energy, different setups of drop-weight impact tests might lead to different ...
-
Li, H.; Chen, Wensu ; Hao, Hong (2019)© 2019 Elsevier Ltd A number of drop weight tests on reinforced concrete (RC) beams have been reported in literature. These tests conducted by different researchers used drop weight of different geometries. Some researchers ...
-
Hao, Y.; Hao, Hong; Chen, G. (2014)Concrete is a brittle material with much lower strength in tension as compared to that in compression. Adding fibres into concrete mix has been intensively investigated to increase the ductility, the crack control and ...