Show simple item record

dc.contributor.authorWinkler, E.
dc.contributor.authorBodicoat, D.
dc.contributor.authorHealy, Genevieve
dc.contributor.authorBakrania, K.
dc.contributor.authorYates, T.
dc.contributor.authorOwen, N.
dc.contributor.authorDunstan, D.
dc.contributor.authorEdwardson, C.
dc.date.accessioned2017-01-30T11:12:25Z
dc.date.available2017-01-30T11:12:25Z
dc.date.created2016-11-16T19:30:22Z
dc.date.issued2016
dc.identifier.citationWinkler, E. and Bodicoat, D. and Healy, G. and Bakrania, K. and Yates, T. and Owen, N. and Dunstan, D. et al. 2016. Identifying adults' valid waking wear time by automated estimation in activPAL data collected with a 24 h wear protocol. Physiological Measurement. 37 (10): pp. 1653-1668.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/9395
dc.identifier.doi10.1088/0967-3334/37/10/1653
dc.description.abstract

© 2016 Institute of Physics and Engineering in Medicine.The activPAL monitor, often worn 24 h d-1, provides accurate classification of sitting/reclining posture. Without validated automated methods, diaries-burdensome to participants and researchers-are commonly used to ensure measures of sedentary behaviour exclude sleep and monitor non-wear. We developed, for use with 24 h wear protocols in adults, an automated approach to classify activity bouts recorded in activPAL 'Events' files as 'sleep'/non-wear (or not) and on a valid day (or not). The approach excludes long periods without posture change/movement, adjacent low-active periods, and days with minimal movement and wear based on a simple algorithm. The algorithm was developed in one population (STAND study; overweight/obese adults 18-40 years) then evaluated in AusDiab 2011/12 participants (n = 741, 44% men, aged >35 years, mean ± SD 58.5 ± 10.4 years) who wore the activPAL3™ (7 d, 24 h d-1 protocol). Algorithm agreement with a monitor-corrected diary method (usual practice) was tested in terms of the classification of each second as waking wear (Kappa; ?) and the average daily waking wear time, on valid days. The algorithm showed 'almost perfect' agreement (? > 0.8) for 88% of participants, with a median kappa of 0.94. Agreement varied significantly (p < 0.05, two-tailed) by age (worsens with age) but not by gender. On average, estimated wear time was approximately 0.5 h d-1 higher than by the diary method, with 95% limits of agreement of approximately this amount ±2 h d-1. In free-living data from Australian adults, a simple algorithm developed in a different population showed 'almost perfect' agreement with the diary method for most individuals (88%). For several purposes (e.g. with wear standardisation), adopting a low burden, automated approach would be expected to have little impact on data quality. The accuracy for total waking wear time was less and algorithm thresholds may require adjustments for older populations.

dc.publisherInstitute of Physics Publishing Ltd
dc.titleIdentifying adults' valid waking wear time by automated estimation in activPAL data collected with a 24 h wear protocol
dc.typeJournal Article
dcterms.source.volume37
dcterms.source.number10
dcterms.source.startPage1653
dcterms.source.endPage1668
dcterms.source.issn0967-3334
dcterms.source.titlePhysiological Measurement
curtin.departmentSchool of Physiotherapy and Exercise Science
curtin.accessStatusOpen access via publisher


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record