Show simple item record

dc.contributor.authorJones, E.C.
dc.contributor.authorHooper, J.F.L.
dc.contributor.authorBouzin, J.T.
dc.contributor.authorWilson, R.
dc.contributor.authorLewis, Simon
dc.date.accessioned2024-09-20T07:51:41Z
dc.date.available2024-09-20T07:51:41Z
dc.date.issued2024
dc.identifier.citationJones, E.C. and Hooper, J.F.L. and Bouzin, J.T. and Wilson, R. and Lewis, S.W. 2024. Amino acid sensitive latent fingermark detection formulations based upon improvised carrier solvents for resource-limited environments: A proof-of-concept study. Forensic Science International: Reports. : pp. 100388-.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/95923
dc.identifier.doi10.1016/j.fsir.2024.100388
dc.description.abstract

HFE-7100 and petroleum ether (bp 40–60 °C) are routine carrier solvents used in amino acid sensitive fingermark reagents such as 1,2-indanedione/zinc chloride (IND-Zn) and ninhydrin. However, limited resource jurisdictions face major challenges in sourcing laboratory-grade reagents due to budgetary and geographical restrictions. Common hydrocarbon solvents, available from hardware stores and similar outlets, may offer a more readily available and inexpensive alternative for such jurisdictions. This study assessed the range of improvised carrier solvents for their suitability in the IND-Zn formulation and found that eight different hydrocarbon solvents were able to develop fingermarks when substituted into the formulation. The formulation based on shellite solvent outperformed all other improvised formulations tested, providing high-quality fingermarks and similar sensitivity to a petroleum ether (bp 40–60 °C) based formulation across six porous substrates using six donors. A similar approach was applied to ninhydrin, where it was discovered that formulations using kerosene, white spirits and shellite as carrier solvents performed comparably to a formulation based on petroleum ether (bp 40–60 °C). By chemically characterising each solvent using gas chromatography-mass spectrometry, this study also provided a greater understanding of how the chemical composition of a carrier solvent impacts the efficacy of the resulting IND-Zn formulation, emphasising that hydrocarbon solvents should contain short-chain alkanes and minimal aromatic content to give a more volatile formulation. Additionally, the identity of the solvent was found to cause slight differences in the colour and luminescence intensity of ink diffusion on porous substrates. These results indicate that improvised hydrocarbon solvents are suitable alternatives to common carrier solvents with their operational use offering major benefits for limited resource jurisdictions by reducing costs and supply chain risks. A thorough risk assessment must be conducted by each jurisdiction that intends to use this method as health and safety considerations are concerns with these improvised solvents.

dc.subjectLatent fingermark detection
dc.subject1,2-Indanedione
dc.subjectNinhydrin
dc.subjectCarrier solvents
dc.subjectSustainable development
dc.titleAmino acid sensitive latent fingermark detection formulations based upon improvised carrier solvents for resource-limited environments: A proof-of-concept study
dc.typeJournal Article
dcterms.source.startPage100388
dcterms.source.issn2665-9107
dcterms.source.titleForensic Science International: Reports
dc.date.updated2024-09-20T07:51:40Z
curtin.departmentSchool of Molecular and Life Sciences (MLS)
curtin.accessStatusIn process
curtin.facultyFaculty of Science and Engineering
curtin.contributor.orcidLewis, Simon [0000-0002-2049-1586]
curtin.contributor.scopusauthoridLewis, Simon [7404038754]
curtin.repositoryagreementV3


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record