Dual-Tracer PET Using Generalized Factor Analysis of Dynamic Sequences
Access Status
Authors
Date
2013Type
Metadata
Show full item recordCitation
Source Title
Additional URLs
ISSN
Collection
Abstract
Purpose: With single-photon emission computed tomography, simultaneous imaging of two physiological processes relies on discrimination of the energy of the emitted gamma rays, whereas the application of dual-tracer imaging to positron emission tomography (PET) imaging has been limited by the characteristic 511-keV emissions.Procedures: To address this limitation, we developed a novel approach based on generalized factor analysis of dynamic sequences (GFADS) that exploits spatio-temporal differences between radiotracers and applied it to near-simultaneous imaging of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) (brain metabolism) and 11C-raclopride (D2) with simulated human data and experimental rhesus monkey data. We show theoretically and verify by simulation and measurement that GFADS can separate FDG and raclopride measurements that are made nearly simultaneously. Results: The theoretical development shows that GFADS can decompose the studies at several levels: (1) It decomposes the FDG and raclopride study so that they can be analyzed as though they were obtained separately. (2) If additional physiologic/anatomic constraints can be imposed, further decomposition is possible. (3) For the example of raclopride, specific and nonspecific binding can be determined on a pixel-by-pixel basis. We found good agreement between the estimated GFADS factors and the simulated ground truth time activity curves (TACs), and between the GFADS factor images and the corresponding ground truth activity distributions with errors less than 7.3±1.3 %. Biases in estimation of specific D2 binding and relative metabolism activity were within 5.9±3.6 % compared to the ground truth values. We also evaluated our approach in simultaneous dual-isotope brain PET studies in a rhesus monkey and obtained accuracy of better than 6 % in a mid-striatal volume, for striatal activity estimation. Conclusions: Dynamic image sequences acquired following near-simultaneous injection of two PET radiopharmaceuticals can be separated into components based on the differences in the kinetics, provided their kinetic behaviors are distinct.
Related items
Showing items related by title, author, creator and subject.
-
Zhang, Li (2009)This research aims to address one of the most challenging problems in the field of computer vision and computer graphics, that is, the reconstruction of smooth 3D human motions from monocular video containing unrestricted ...
-
LeCras, Jared; Paxman, Jonathan; Saracik, Brad (2013)A dynamic light source poses significant challenges to vision based localization algorithms. There are a number of real world scenarios where dynamic illumination may be a factor, yet robustness to dynamic lighting is not ...
-
Terdkiatburana, Thanet (2007)Humic substances are macromolecules that naturally occur in all environments in which vegetation matter are present. In general, humic acid is part of humic substances which form the major fraction of the dissolved organic ...