Improvement of DFIG Dynamic Performance during Intermittent Fire-Through Fault
Access Status
Authors
Date
2015Type
Metadata
Show full item recordCitation
Source Title
Source Conference
ISBN
School
Remarks
Copyright © 2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
Collection
Abstract
The number of wind turbines connected to power grids have significantly increased during the last decade. This is mainly due to the convincing revolution in power electronic technology and the growing concern about greenhouse effect that is intensified due to the burning of fossil fuels. Variable-speed wind energy conversion systems (WECSs) such as doubly fed induction generators (DFIGs) are dominating the wind energy market due to their superior advantages over fixed-speed-based WECS which include more captured energy, less mechanical stress, and acoustical noise. DFIG is interfaced to the ac network through the grid-side voltage source converter (GSC) and rotor-side RSC to enable the variable-speed operation of the wind turbine and to provide reactive power support to the ac grid during disturbance events. Converter switching malfunction such as fire-through may influence the power dispatch capability of the DFIG. In this paper, a coil is proposed to be integrated within the DFIG converters to improve dynamic performance of DFIG-based WECS during internal converter switching malfunctions such as fire-through fault. Simulation results without and with the coil connected to the system are presented.
Related items
Showing items related by title, author, creator and subject.
-
Mohseni, Mansour (2011)A review of the latest international grid codes shows that large wind power plants are stipulated to not only ride-through various fault conditions, but also exhibit adequate active and reactive power responses during the ...
-
Yunus, A. M. Shiddiq (2012)Due to the rising demand of energy over several decades, conventional energy resources have been continuously and drastically explored all around the world. As a result, global warming is inevitable due to the massive ...
-