Impact of DC-link fault on the dynamic performance of DFIG
Access Status
Authors
Date
2012Type
Metadata
Show full item recordCitation
Source Title
Source Conference
ISBN
ISSN
Remarks
Copyright © 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
Collection
Abstract
The number of doubly fed induction generators (DFIG) connected to the existing network has increased significantly worldwide during the last two decades. This triggers off manufactures to improve the performance of DFIG through robust and reliable design. The stator in DFIG is directly connected to the grid whereas the rotor is interfaced to the grid through two voltage source converters; rotor side converter (RSC) and grid side converter (GSC), which are considered as the crux of the DFIG system. The converter stations determine the ability of wind turbine to operate optimally during wind speed fluctuation and it can provide reactive power support to the grid during grid disturbance events. The DC capacitor link between the two converters allows optimum and smooth power exchange between DFIG and the grid. Therefore, any faults within the DC link will affect the overall performance of the DFIG. This paper investigates the impact of open circuit and short circuit faults in the DC link capacitor on the dynamic performance of the DFIG. The compliance of the wind energy conversion (WEC) system with different grid codes such as those of Denmark, Spain, Nordic and Sweden under such faults is also investigated.
Related items
Showing items related by title, author, creator and subject.
-
Mohseni, Mansour (2011)A review of the latest international grid codes shows that large wind power plants are stipulated to not only ride-through various fault conditions, but also exhibit adequate active and reactive power responses during the ...
-
Yunus, A. M. Shiddiq (2012)Due to the rising demand of energy over several decades, conventional energy resources have been continuously and drastically explored all around the world. As a result, global warming is inevitable due to the massive ...
-
Abdou, A.; Abu-Siada, Ahmed; Pota, H (2013)The sensitivity of the doubly fed induction generator (DFIG) to external faults has motivated researchers to investigate the impact of various grid disturbances such as voltage sag and short circuit faults on the fault ...