Show simple item record

dc.contributor.authorWang, T.
dc.contributor.authorLin, Z.
dc.contributor.authorNi, M.
dc.contributor.authorThien, C.
dc.contributor.authorDay, R.
dc.contributor.authorGardiner, B.
dc.contributor.authorRubenson, J.
dc.contributor.authorKirk, Brett
dc.contributor.authorSmith, D.
dc.contributor.authorWang, A.
dc.contributor.authorLloyd, D.
dc.contributor.authorWang, Y.
dc.contributor.authorZheng, Q.
dc.contributor.authorZheng, M.
dc.date.accessioned2017-01-30T11:59:24Z
dc.date.available2017-01-30T11:59:24Z
dc.date.created2015-12-10T04:26:02Z
dc.date.issued2015
dc.identifier.citationWang, T. and Lin, Z. and Ni, M. and Thien, C. and Day, R. and Gardiner, B. and Rubenson, J. et al. 2015. Cyclic mechanical stimulation rescues achilles tendon from degeneration in a bioreactor system. Journal of Orthopaedic Research. 33 (12): pp. 1888-1896.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/17055
dc.identifier.doi10.1002/jor.22960
dc.description.abstract

Physiotherapy is one of the effective treatments for tendinopathy, whereby symptoms are relieved by changing the biomechanical environment of the pathological tendon. However, the underlying mechanism remains unclear. In this study, we first established a model of progressive tendinopathy-like degeneration in the rabbit Achilles. Following ex vivo loading deprivation culture in a bioreactor system for 6 and 12 days, tendons exhibited progressive degenerative changes, abnormal collagen type III production, increased cell apoptosis, and weakened mechanical properties. When intervention was applied at day 7 for another 6 days by using cyclic tensile mechanical stimulation (6% strain, 0.25Hz, 8h/day) in a bioreactor, the pathological changes and mechanical properties were almost restored to levels seen in healthy tendon. Our results indicated that a proper biomechanical environment was able to rescue early-stage pathological changes by increased collagen type I production, decreased collagen degradation and cell apoptosis. The ex vivo model developed in this study allows systematic study on the effect of mechanical stimulation on tendon biology.

dc.publisherJohn Wiley and Sons Inc.
dc.titleCyclic mechanical stimulation rescues achilles tendon from degeneration in a bioreactor system
dc.typeJournal Article
dcterms.source.volume33
dcterms.source.number12
dcterms.source.startPage1888
dcterms.source.endPage1896
dcterms.source.issn0736-0266
dcterms.source.titleJournal of Orthopaedic Research
curtin.departmentOffice of Research and Development
curtin.accessStatusOpen access via publisher


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record