Impact of DC link faults on the performance of full converter based WECS
dc.contributor.author | Yunus, A. | |
dc.contributor.author | Abu Siada, Ahmed | |
dc.contributor.author | Masoum, Mohammad Sherkat | |
dc.contributor.author | Islam, Syed | |
dc.contributor.editor | Nabil Abbasy | |
dc.date.accessioned | 2017-01-30T12:45:55Z | |
dc.date.available | 2017-01-30T12:45:55Z | |
dc.date.created | 2013-02-19T20:00:30Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Yunus, A. M. Shiddiq and Abu-Siada, A. and Masoum, M.A.S. and Islam, Syed M. 2012. Impact of DC link faults on the performance of full converter based WECS, in Proceedings of the Fifteenth International Middle East Power Systems Conference (MEPCON ’12), Dec 23-25 2012. Alexandria, Egypt: Alexandria University. | |
dc.identifier.uri | http://hdl.handle.net/20.500.11937/24943 | |
dc.description.abstract |
The number of full converter based wind energy conversion system (FCWECS) connected to the electricity grids have increased significantly worldwide during the last decade. This triggers off manufactures to improve the performance of FCWECS through robust and reliable designs. FCWECS is interfaced with the grid through voltage source inverter (VSI) and rectifier which are considered as the crux of the FCWECS system. The VSI determines the ability of wind turbine to operate optimally during wind speed fluctuation and it can provide reactive power support to the grid during grid disturbance events. The DC capacitor link between the rectifier and the VSI allows optimum and smooth power transfer between FCWECS and the grid. Therefore, any faults within the DC link will affect the overall performance of the FCWECS. This paper investigates the impact of short circuit and open circuit faults across the DC link capacitor on the dynamic performance of the FCWECS. The compliance of the wind energy conversion system (WECS) with different grid codes such as those of Denmark, Spain, Nordic and Sweden under such faults is also investigated. | |
dc.publisher | Faculty of Engineering, Alexandria University | |
dc.subject | fault ride through | |
dc.subject | voltage source inverter | |
dc.subject | FCWECS | |
dc.title | Impact of DC link faults on the performance of full converter based WECS | |
dc.type | Conference Paper | |
dcterms.source.title | Fifteenth International Middle East Power Systems Conference | |
dcterms.source.series | Fifteenth International Middle East Power Systems Conference | |
dcterms.source.conference | Fifteenth International Middle East Power Systems Conference | |
dcterms.source.conference-start-date | Dec 23 2012 | |
dcterms.source.conferencelocation | Alexandria, Egypt | |
dcterms.source.place | Egypt | |
curtin.note |
The Abstract may be accessible from the link in the Related Links field | |
curtin.department | ||
curtin.accessStatus | Fulltext not available |