    Development of pressure-impulse curves for Fiber Reinforced Polymer strengthened reinforced concrete walls

    Access Status
    Fulltext not available
    Authors
    Mutalib, A.
    Hao, Hong
    Date
    2011
    Type
    Book Chapter
    
    Metadata
    Show full item record
    Citation
    Mutalib, A. and Hao, H. 2011. Development of pressure-impulse curves for Fiber Reinforced Polymer strengthened reinforced concrete walls, in Fragomeni, S. and Venkatesan, S. (ed), Incorporating Sustainable Practice in Mechanics and Structures of Materials, pp. 487-492. London: Taylor and Francis.
    Source Title
    Incorporating Sustainable Practice in Mechanics of Structures and Materials - Proceedings of the 21st Australian Conference on the Mechanics of Structures and Materials
    DOI
    10.1201/b10571-86
    ISBN
    9780415616577
    School
    Department of Civil Engineering
    URI
    http://hdl.handle.net/20.500.11937/30768
    Collection
    • Curtin Research Publications
    Abstract

    Most research on using Fiber Reinforced Polymer (FRP) to repair and strengthen reinforced concrete structures to resist blast and impact loads are experimentally based. Little quantitative information relating the capacity increament with the FRP strengthening measures is available, and some inconsistent conclusions exist in the literature. It was found that in general FRP strengthening, if it is properly applied onto the RC wall and premature debonding of FRP layers from RC wall is prevented, will increase the wall's capacity in resisting blast loadings. The FRP layer is also a good catchment system to stop concrete debris for personnel protection. In this study, numerical simulations are carried out to construct pressure-impulse (P-I) curves of FRP strengthened RC walls. Damage criteria given in technical manual TM5-1300 based on the support rotation are used. Influences of RC wall and FRP properties on P-I curves are studied. The generated P-I curves can be used in primary assessment of RC wall structural damage to blast loads.

    Related items

    Showing items related by title, author, creator and subject.

    • Experimental and numerical study on CFRP strip strengthened clay brick masonry walls subjected to vented gas explosions
      Li, Zhan ; Chen, L.; Fang, Q.; Chen, Wensu ; Hao, Hong ; Zhu, R.; Zheng, K. (2019)
      © 2019 Elsevier Ltd A total of nine full-scale field blast tests were conducted in a specially designed reinforced concrete (RC) chamber to investigate the performance of carbon fiber reinforced polymer (CFRP) strip ...
    • Numerical analysis of FRP-composite-strengthened RC panels with anchorages against blast loads
      Mutalib, A.; Hao, Hong (2011)
      Extensive research has been conducted to investigate the blast effects on building structures and the protective design methods using the fiber-reinforced polymer (FRP) strengthening concepts in resisting structural damage ...
    • Experimental and numerical study of basalt fiber reinforced polymer strip strengthened autoclaved aerated concrete masonry walls under vented gas explosions
      Li, Zhan; Chen, L.; Fang, Q.; Chen, Wensu; Hao, Hong; Zhang, Y. (2017)
      © 2017 Elsevier Ltd Ten full-scale field tests were conducted to study the performance of basalt fiber reinforced polymer (BFRP) strip strengthened autoclaved aerated concrete (AAC) masonry walls subjected to vented gas ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.