    High-Pitch, Low-Voltage and Low-Iodine-Concentration CT Angiography of Aorta: Assessment of Image Quality and Radiation Dose with Iterative Reconstruction

    228303_162359_Sun_Plos_One_2015.pdf (1.826Mb)
    Access Status
    Open access
    Authors
    Shen, Y.
    Sun, Zhonghua
    Xu, L.
    Li, Y.
    Zhang, N.
    Yan, Z.
    Fan, Z.
    Date
    2015
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Shen, Y. and Sun, Z. and Xu, L. and Li, Y. and Zhang, N. and Yan, Z. and Fan, Z. 2015. High-Pitch, Low-Voltage and Low-Iodine-Concentration CT Angiography of Aorta: Assessment of Image Quality and Radiation Dose with Iterative Reconstruction. PLoS One. 10 (2): pp. e0117469.
    Source Title
    PLoS One
    DOI
    10.1371/journal.pone.0117469
    ISSN
    1932-6203
    School
    Department of Medical Radiation Sciences
    Remarks

    This open access article is distributed under the Creative Commons license http://creativecommons.org/licenses/by/4.0/

    URI
    http://hdl.handle.net/20.500.11937/37352
    Collection
    • Curtin Research Publications
    Abstract

    Objective: To assess the image quality of aorta obtained by dual-source computed tomography angiography (DSCTA), performed with high pitch, low tube voltage, and low iodine concentration contrast medium (CM) with images reconstructed using iterative reconstruction (IR). Methods: One hundred patients randomly allocated to receive one of two types of CM underwent DSCTA with the electrocardiogram-triggered Flash protocol. In the low-iodine group, 50 patients received CM containing 270 mg I/mL and were scanned at low tube voltage (100 kVp). In the high-iodine CM group, 50 patients received CM containing 370 mg I/mL and were scanned at the tube voltage (120 kVp). The filtered back projection (FBP) algorithm was used for reconstruction in both groups. In addition, the IR algorithm was used in the low-iodine group. Image quality of the aorta was analyzed subjectively by a 3-point grading scale and objectively by measuring the CT attenuation in terms of the signal- and contrast-to-noise ratios (SNR and CNR, respectively). Radiation and CM doses were compared.Results: The CT attenuation, subjective image quality assessment, SNR, and CNR of various aortic regions of interest did not differ significantly between two groups. In the low-iodine group, images reconstructed by FBP and IR demonstrated significant differences in image noise, SNR, and CNR (p<0.05). The low-iodine group resulted in 34.3% less radiation (4.4 ± 0.5 mSv) than the high-iodine group (6.7 ± 0.6 mSv), and 27.3% less iodine weight (20.36 ± 2.65 g) than the high-iodine group (28 ± 1.98 g). Observers exhibited excellent agreement on the aortic image quality scores (κ = 0.904). Conclusions: CT images of aorta could be obtained within 2 s by using a DSCT Flash protocol with low tube voltage, IR, and low-iodine-concentration CM. Appropriate contrast enhancement was achieved while maintaining good image quality and decreasing the radiation and iodine doses.

    Related items

    Showing items related by title, author, creator and subject.

    • High Pitch Dual-Source Whole Aorta CT Angiography in the Detection of Coronary Arteries: A Feasibility Study of Using Iodixanol 270 and 100 kVp with Iterative Reconstruction
      Shen, Y.; Fan, Z.; Sun, Zhonghua; Xu, L.; Li, Y.; Zhang, N.; Yan, Z. (2015)
      To assess the feasibility of detecting coronary arteries through high-pitch dual-source computed tomography (DSCT) thoracoabdominal angiography when using low-concentration contrast medium, low tube voltage, and iterative ...
    • Optimization of computed tomography pulmonary angiography protocols using 3D printed model with simulation of pulmonary embolism
      Aldosari, S.; Jansen, S.; Sun, Zhonghua (2018)
      Background: Three-dimensional (3D) printing has been shown to accurately replicate anatomical structures and pathologies in complex cardiovascular disease. Application of 3D printed models to simulate pulmonary arteries ...
    • Low tube voltage prospectively ECG-triggered coronary CT angiography: A systematic review of image quality and radiation dose
      Tan, S.; Yeong, C.; Raja Aman, R.; Ng, K.; Abdul Aziz, Y.; Chee, K.; Sun, Zhonghua (2018)
      OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.