Show simple item record

dc.contributor.authorLee, Junqiao
dc.contributor.authorArrigan, Damien
dc.contributor.authorSilvester, Debbie
dc.date.accessioned2017-01-30T15:02:44Z
dc.date.available2017-01-30T15:02:44Z
dc.date.created2016-06-14T19:30:13Z
dc.date.issued2016
dc.identifier.citationLee, J. and Arrigan, D. and Silvester, D. 2016. Achievement of prolonged oxygen detection in room-temperature ionic liquids on mechanically polished platinum screen-printed electrodes. Analytical Chemistry. 88 (10): pp. 5104-5111.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/42865
dc.identifier.doi10.1021/acs.analchem.5b04782
dc.description.abstract

The demonstration of prolonged amperometric detection of oxygen in room-temperature ionic liquids (RTILs) was achieved by the use of mechanical polishing to activate platinum screen-printed electrodes (Pt-SPEs). The RTILs studied were 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) and N-butyl-N-methyl-pyrrolidinium bis(trifluoromethylsulfonyl)imide ([C4mpyrr][NTf2]). It was found that voltammetry on polished Pt-SPEs exhibited less deterioration (in terms of voltammogram shapes, stability of peak currents, and appearance of contaminant peaks) from long-term consecutive cycling under 100% vol oxygen flow in both RTILs. The detection capability of these RTIL/Pt-SPE systems, initially subjected to long-term consecutive voltammetric cycling, was also investigated by cyclic voltammetry (CV) and long-term chronoamperometry (LTCA). Current versus concentration plots were linear on both unpolished and polished electrodes for 10-100% vol O2 (using CV) and 0.1-5% vol O2 (using LTCA). However, sensitivities and limits of detection (LODs) from CV were found to improve significantly on polished electrodes compared to unpolished electrodes, particularly in [C2mim][NTf2], but also moderately in [C4mpyrr][NTf2]. The lowest LODs (of ca. 0.1% vol O2) were found on polished SPEs using LTCA, with the most stable responses observed in [C4mpyrr][NTf2]. Calibration graphs could not be obtained on unpolished electrodes in both RTILs using LTCA. The results show that polishing markedly improves the analytical performances of Pt-SPEs for oxygen sensing in RTILs. The reusability of such disposable Pt-SPEs, after the surfaces had been experimentally fouled, was also demonstrated through the use of polishing. Mechanical polishing of Pt-SPE devices offers a viable approach to performance improvement for amperometric gas sensing. © 2016 American Chemical Society.

dc.publisherAmerican Chemical Society
dc.relation.sponsoredbyhttp://purl.org/au-research/grants/arc/DE120101456
dc.titleAchievement of prolonged oxygen detection in room-temperature ionic liquids on mechanically polished platinum screen-printed electrodes
dc.typeJournal Article
dcterms.source.volume88
dcterms.source.number10
dcterms.source.startPage5104
dcterms.source.endPage5111
dcterms.source.issn0003-2700
dcterms.source.titleAnalytical Chemistry
curtin.note

This document is the Accepted Manuscript version of a Published Work that appeared in final form in Analytical Chemistry, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see http://doi.org/10.1021/acs.analchem.5b04782, see http://pubs.acs.org/page/policy/articlesonrequest/index.html

curtin.departmentNanochemistry Research Institute
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record