Optimisation of paediatrics computed radiography for full spine curvature measurements using a phantom: a pilot study
Access Status
Authors
Date
2014Type
Metadata
Show full item recordCitation
Source Title
Additional URLs
ISBN
School
Remarks
This open access article is distributed under the Creative Commons license http://creativecommons.org/licenses/by-nc-sa/
Collection
Abstract
Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.
Related items
Showing items related by title, author, creator and subject.
-
Sabarudin, Akmal (2012)Prospective ECG-triggering is regarded as one of the most effective approaches for reduction of radiation dose to patients during coronary CT angiography (CCTA). This study was conducted to investigate the diagnostic ...
-
Sun, Zhonghua; Siddiqu, S.; Ng, K.; Ramli, K.; Davidson, R. (2007)Introduction: In chest radiographic imaging, computed radiography (CR) has been replacing the conventional film-screen imaging technology. Selection of the appropriate radiation quality is an important aspect of optimisation ...
-
Sun, Zhonghua; Ng, Curtise (2010)Rationale and Objectives: The aim of the study was to investigate the optimal protocols of dual-source computed tomography (CT) angiographyin aortic stent grafting in terms of image noise and radiation dose, based on an ...