Analytical bias in the measurement of serum 25-hydroxyvitamin D concentrations impairs assessment of vitamin D status in clinical and research settings
Access Status
Authors
Date
2015Type
Metadata
Show full item recordCitation
Source Title
ISSN
School
Collection
Abstract
Measured serum 25-hydroxyvitamin D concentrations vary depending on the type of assay used and the specific laboratory undertaking the analysis, impairing the accurate assessment of vitamin D status. We investigated differences in serum 25-hydroxyvitamin D concentrations measured at three laboratories (laboratories A and B using an assay based on liquid chromatography-tandem mass spectrometry and laboratory C using a DiaSorin Liaison assay), against a laboratory using an assay based on liquid chromatography-tandem mass spectrometry that is certified to the standard reference method developed by the National Institute of Standards and Technology and Ghent University (referred to as the ‘ certified laboratory ’ ). Separate aliquots from the same original serum sample for a subset of 50 participants from the Ausimmune Study were analysed at the four laboratories. Bland-Altman plots were used to visually check agreement between each laboratory against the certified laboratory. Compared with the certified laboratory, serum 25-hydroxyvitamin D concentrations were on average 12.4 nmol/L higher at laboratory A (95% limits of agreement: -17 .8,42.6); 12.8 nmol/L higher at laboratory B (95% limits of agreement: 0.8,24.8); and 10.6 nmol/L lower at laboratory C (95% limits of agreement: -48.4,27.1). The prevalence of vitamin D deficiency (defined here as 25-hydroxyvitamin D < 50 nmol/L) was 24%, 16%, 12% and 41% at the certified laboratory, and laboratories A, B, and C, respectively. Our results demonstrate considerable differences in the measurement of 25-hydroxyvitamin D concentrations compared with a certified laboratory, even between laboratories using assays based on liquid chromatography-tandem mass spectrometry, which is often considered the gold-standard assay. To ensure accurate and reliable measurement of serum 25-hydroxyvitamin D concentrations, all laboratories should use an accuracy-based quality assurance system and, ideally, comply with international standardisation efforts
Related items
Showing items related by title, author, creator and subject.
-
Black, Lucinda; Anderson, D.; Clarke, M.; Ponsonby, A.; Lucas, R. (2015)Measured serum 25-hydroxyvitamin D concentrations vary depending on the type of assay used and the specific laboratory undertaking the analysis, impairing the accurate assessment of vitamin D status. We investigated ...
-
Black, Lucinda; Jacoby, P.; Burrows, S.; Oddy, W.; Beilin, L.; She Ping-Delfos, W.; Marshall, C.; Holt, P.; Hart, P.; Mori, Takeshi (2014)Despite the importance of skeletal growth during adolescence, there is limited research reporting vitamin D status and its predictors in adolescents. Using prospective data from the Western Australian Pregnancy Cohort ...
-
Malacova, Eva; Cheang, P.; Dunlop, E.; Sherriff, Jill; Lucas, R.; Daly, R.; Nowson, C.; Black, Lucinda (2019)Vitamin D deficiency is recognised as a public health problem globally, and a high prevalence of deficiency has previously been reported in Australia. This study details the prevalence of vitamin D deficiency in a nationally ...