    Software implementation of two seamless redundant topologies in a digital protection system based on IEC 62439-3

    Access Status
    Fulltext not available
    Authors
    Kumar, S.
    Das, N.
    Islam, Syed
    Date
    2016
    Type
    Conference Paper
    
    Metadata
    Show full item record
    Citation
    Kumar, S. and Das, N. and Islam, S. 2016. Software implementation of two seamless redundant topologies in a digital protection system based on IEC 62439-3, in Proceedings of the Australasian Universities Power Engineering Conference- AUPEC, Sep 25-28 2016, pp. 203. Brisbane, Australia: IEEE.
    Source Title
    Proceedings of the 2016 Australasian Universities Power Engineering Conference, AUPEC 2016
    DOI
    10.1109/AUPEC.2016.07749323
    ISBN
    9781509014057
    School
    Department of Electrical and Computer Engineering
    URI
    http://hdl.handle.net/20.500.11937/47159
    Collection
    • Curtin Research Publications
    Abstract

    Substations are the junctions of any transmission and distribution network in utilities. They carry bulk power to the customers using transmission network involving high voltage (HV) apparatus. Protection of HV equipment during a fault is the primary concern of an operator. Advancement in design and manufacturing of Intelligent Electronic Devices (IEDs) and IEC 61850 are finding increased application in utilities from automation and communication perspective, which addresses few shortcomings that couldn't be resolved in a conventional system. However there are few challenges in the digital scheme such as end to end delays in the packet transfer and interoperability of devices. Utilities are able to perceive these benefits by leveraging on IEC 62439-3 which has two important topologies i.e. Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR). It offers seamless redundancy in digital protection network without compromising the availability and downtime cost. In this paper, an Optimized Network Engineering Tool (OPNET) is used to simulate and compare the performance of these topologies with respect to delay time.

    Related items

    Showing items related by title, author, creator and subject.

    • Evaluating communication-network reliability with heterogeneous link-capacities using subset enumeration
      Soh, Sieteng; Lim, Kok; Rai, S. (2006)
      This paper proposes an improved algorithm to compute the reliability of a communication-network having heterogeneous link capacities. The reliability measure, capacity related reliability (CRR), is a generalization of a ...
    • High performance communication redundancy in a digital substation based on IEC 62439-3 with a station bus configuration
      Kumar, S.; Das, N.; Islam, Syed (2015)
      High speed communication is critical in a digital substation from protection, control and automation perspectives. Although International Electro-Technical Commission (IEC) 61850 standard has proven to be a reliable guide ...
    • Energy-aware traffic engineering with reliability constraint
      Lin, GongQi; Soh, Sieteng; Chin, K. (2015)
      Current network infrastructures are over-provisioned to increase their resilience against resource failures. Such strategies exhibit poor energy efficiency during off-peak periods. In this respect, energy aware Traffic ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.