Show simple item record

dc.contributor.authorYu, H.
dc.contributor.authorLee, J.
dc.contributor.authorLewis, Simon
dc.contributor.authorSilvester, Debbie
dc.date.accessioned2017-04-28T13:57:30Z
dc.date.available2017-04-28T13:57:30Z
dc.date.created2017-04-28T09:06:03Z
dc.date.issued2017
dc.identifier.citationYu, H. and Lee, J. and Lewis, S. and Silvester, D. 2017. Detection of 2,4,6-Trinitrotoluene Using a Miniaturized, Disposable Electrochemical Sensor with an Ionic Liquid Gel-Polymer Electrolyte Film. Analytical Chemistry. 89 (8): pp. 4729-4736.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/52095
dc.identifier.doi10.1021/acs.analchem.7b00679
dc.description.abstract

A new electrochemical method to detect and quantify the explosive compound 2,4,6-trinitrotoluene (TNT) in aqueous solutions is demonstrated. A disposable thin-film electrode modified with a droplet of a gel-polymer electrolyte (GPE) was immersed directly into samples of TNT at concentrations of 1-10 µg/mL. The GPE contained the hydrophobic room-temperature ionic liquid (RTIL) trihexyltetradecylphosphonium bis(trifluoromethylsulfonyl)imide ([P14,6,6,6][NTf2]) and the polymer poly(hexyl methacrylate). The RTIL acted to preconcentrate TNT into the GPE and provided ionic conductivity. The polymer provided both (i) sufficient viscosity to ensure mechanical stability of the GPE and (ii) strong hydrophobicity to minimize leaching of the RTIL. Square wave voltammetry was performed on the first reduction peak of TNT-preconcentrated samples (15 min soaking with mechanical stirring), with linear plots of peak current vs cumulative concentration of TNT, giving an averaged limit of detection of 0.37 µg/mL (aqueous phase concentration). Additionally, the voltammetry of the first reduction peak of TNT in [P14,6,6,6][NTf2] was unaffected by the presence of oxygen-in contrast to that observed in an imidazolium-based RTIL-providing excellent selectivity over oxygen in real environments. The sensor device was able to quickly and easily quantify TNT concentrations at typical ground water contamination levels. The low-cost and portability of the sensor device, along with the minimal amounts of GPE materials required, make this a viable platform for the onsite monitoring of explosives, which is currently a significant operational challenge.

dc.publisherAmerican Chemical Society
dc.relation.sponsoredbyhttp://purl.org/au-research/grants/arc/DE120101456
dc.titleDetection of 2,4,6-Trinitrotoluene Using a Miniaturized, Disposable Electrochemical Sensor with an Ionic Liquid Gel-Polymer Electrolyte Film
dc.typeJournal Article
dcterms.source.volume89
dcterms.source.number8
dcterms.source.startPage4729
dcterms.source.endPage4736
dcterms.source.issn1520-6882
dcterms.source.titleAnalytical Chemistry
curtin.departmentDepartment of Chemistry
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record