Show simple item record

dc.contributor.authorBabaie, M.
dc.contributor.authorDavari, P.
dc.contributor.authorTalebizadeh, P.
dc.contributor.authorZare, Firuz
dc.contributor.authorRahimzadeh, H.
dc.contributor.authorRistovski, Z.
dc.contributor.authorBrown, R.
dc.date.accessioned2017-08-24T02:22:19Z
dc.date.available2017-08-24T02:22:19Z
dc.date.created2017-08-23T07:21:49Z
dc.date.issued2015
dc.identifier.citationBabaie, M. and Davari, P. and Talebizadeh, P. and Zare, F. and Rahimzadeh, H. and Ristovski, Z. and Brown, R. 2015. Performance evaluation of non-thermal plasma on particulate matter, ozone and CO2 correlation for diesel exhaust emission reduction. Chemical Engineering Journal. 276: pp. 240-248.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/56113
dc.identifier.doi10.1016/j.cej.2015.04.086
dc.description.abstract

© 2015 Elsevier B.V. This study is seeking to investigate the effect of non-thermal plasma technology in the abatement of particulate matter (PM) from the actual diesel exhaust. Ozone (O < inf > 3 < /inf > ) strongly promotes PM oxidation, the main product of which is carbon dioxide (CO < inf > 2 < /inf > ). PM oxidation into the less harmful product (CO < inf > 2 < /inf > ) is the main objective whiles the correlation between PM, O < inf > 3 < /inf > and CO < inf > 2 < /inf > is considered. A dielectric barrier discharge reactor has been designed with pulsed power technology to produce plasma inside the diesel exhaust. To characterise the system under varied conditions, a range of applied voltages from 11kV < inf > PP < /inf > to 21kV < inf > PP < /inf > at repetition rates of 2.5, 5, 7.5 and 10kHz, have been experimentally investigated. The results show that by increasing the applied voltage and repetition rate, higher discharge power and CO < inf > 2 < /inf > dissociation can be obtained. The PM removal efficiency of more than 50% has been achieved during the experiments and high concentrations of ozone on the order of a few hundreds of ppm have been observed at high discharge powers. Furthermore, O < inf > 3 < /inf > , CO < inf > 2 < /inf > and PM concentrations at different plasma states have been analysed for time dependence. Based on this analysis, an inverse relationship between ozone concentration and PM removal has been found and the role of ozone in PM removal in plasma treatment of diesel exhaust has been highlighted.

dc.publisherElsevier BV
dc.titlePerformance evaluation of non-thermal plasma on particulate matter, ozone and CO2 correlation for diesel exhaust emission reduction
dc.typeJournal Article
dcterms.source.volume276
dcterms.source.startPage240
dcterms.source.endPage248
dcterms.source.issn1385-8947
dcterms.source.titleChemical Engineering Journal
curtin.departmentSchool of Electrical Engineering and Computing
curtin.accessStatusFulltext not available