Composite optimal control for the seismic response of a long-span triple-tower suspension bridge
dc.contributor.author | Wang, H. | |
dc.contributor.author | Wu, Y. | |
dc.contributor.author | Sha, B. | |
dc.contributor.author | Bi, Kaiming | |
dc.contributor.author | Li, A. | |
dc.date.accessioned | 2018-01-30T08:00:12Z | |
dc.date.available | 2018-01-30T08:00:12Z | |
dc.date.created | 2018-01-30T05:59:00Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Wang, H. and Wu, Y. and Sha, B. and Bi, K. and Li, A. 2017. Composite optimal control for the seismic response of a long-span triple-tower suspension bridge, in Hao, H. and Zhang, C. (eds), Proceedings of the 24th Australasian Conference on the Mechanics of Structures and Materials (ACMSM24), Dec 6-9 2016, pp. 1587-1593. Perth: ACMSM. | |
dc.identifier.uri | http://hdl.handle.net/20.500.11937/60383 | |
dc.description.abstract |
In the design of super-long-span suspension bridges, the floating system is commonly adopted. To preclude the possible excessive Longitudinal Displacement (LD), various methods were proposed in the previous studies. In this paper, the Taizhou Bridge, a triple-tower suspension bridge with the longest main span in the world, is taken as an example to demonstrate the effectiveness of using three different approaches, i.e. installing elastic links between the main girder and the towers, installing viscous dampers and combined installing of elastic links and viscous dampers (a so called composite control method), to mitigate the possible excessive LD. A total of 24 cases with different parameters of the elastic links and viscous dampers are investigated to examine the effectiveness of the three different methods. It is observed that the mitigation effect of the 24 cases varies significantly with different parameters. To obtain the optimal control of the triple-tower suspension bridge, the modified Analytic Hierarchy Process (AHP) method is introduced at the end of the paper and the steps of the method are explained in detail. Optimized results show that the LD of the girder is reduced significantly by 65.3% while the inner force of towers does not increase excessively. | |
dc.title | Composite optimal control for the seismic response of a long-span triple-tower suspension bridge | |
dc.type | Conference Paper | |
dcterms.source.startPage | 1587 | |
dcterms.source.endPage | 1593 | |
dcterms.source.title | Mechanics of Structures and Materials: Advancements and Challenges - Proceedings of the 24th Australasian Conference on the Mechanics of Structures and Materials, ACMSM24 2016 | |
dcterms.source.series | Mechanics of Structures and Materials: Advancements and Challenges - Proceedings of the 24th Australasian Conference on the Mechanics of Structures and Materials, ACMSM24 2016 | |
dcterms.source.isbn | 9781138029934 | |
curtin.department | School of Civil and Mechanical Engineering (CME) | |
curtin.accessStatus | Fulltext not available |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |