Curtin University Homepage
  • Library
  • Help
    • Admin

    espace - Curtin’s institutional repository

    JavaScript is disabled for your browser. Some features of this site may not work without it.
    View Item 
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item

    The effects of the removal of electronic devices for 48 hours on sleep in elite judo athletes

    Access Status
    Fulltext not available
    Authors
    Dunican, I.
    Martin, D.
    Halson, S.
    Reale, R.
    Dawson, B.
    Caldwell, J.
    Jones, M.
    Eastwood, Peter
    Date
    2017
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Dunican, I. and Martin, D. and Halson, S. and Reale, R. and Dawson, B. and Caldwell, J. and Jones, M. et al. 2017. The effects of the removal of electronic devices for 48 hours on sleep in elite judo athletes. Journal of Strength and Conditioning Research. 31 (10): pp. 2832-2839.
    Source Title
    Journal of Strength and Conditioning Research
    ISSN
    1064-8011
    School
    School of Physiotherapy and Exercise Science
    URI
    http://hdl.handle.net/20.500.11937/63535
    Collection
    • Curtin Research Publications
    Abstract

    © 2017 National Strength and Conditioning Association. This study examined the effects of evening use of electronic devices (i.e., smartphones, etc.) on sleep quality and next-day athletic and cognitive performance in elite judo athletes. Over 6 consecutive days and nights, 23 elite Australian judo athletes were monitored while attending a camp at the Australian Institute of Sport (AIS). In 14 athletes, all electronic devices were removed on days 3 and 4 (i.e., for 48 hours: the 'device-restricted group'), whereas 9 were permitted to use their devices throughout the camp (the 'control group'). All athletes wore an activity monitor (Readiband) continuously to provide measures of sleep quantity and quality. Other self-reported (diary) measures included time in bed, electronic device use, and rate of perceived exertion during training periods. Cognitive perfor mance (Cogstate) and physical performance (single leg triple hop test) were also measured. When considering night 2 as a 'baseline' for each group, removal of electronic devices on nights 3 and 4 (devicerestricted group) resulted in no significant differences in any sleep-related measure between the groups. When comparing actigraphy-based measures of sleep to subjective measures, all athletes significantly overestimated sleep duration by 58 ± 85 minutes (p = 0.001) per night and underestimated time of sleep onset by 37 ± 72 minutes (p = 0.001) per night. No differences in physical or cognitive function were observed between the groups. Conclusion: This study has shown that the removal of electronic devices for a period of two nights (48 hours) during a judo camp does not affect sleep quality or quantity or influence athletic or cognitive performance.

    Related items

    Showing items related by title, author, creator and subject.

    • Evening electronic device use and sleep patterns in athletes
      Jones, M.; Dawson, B.; Gucciardi, Daniel; Eastwood, Peter; Miller, J.; Halson, S.; Dunican, I.; Peeling, P. (2018)
      The present study aimed to investigate pre-sleep behaviours (including evening electronic device use) and sleep quantity in well-trained athletes. Seventy well-trained athletes (44 females, 26 males) aged 21 ± 4 y from a ...
    • Hypoglossal nerve stimulation improves obstructive sleep apnea: 12-month outcomes
      Kezirian, E.; Goding, G.; Malhotra, A.; O'Donoghue, F.; Zammit, G.; Wheatley, J.; Catcheside, P.; Smith, P.; Schwartz, A.; Walsh, J.; Maddison, K.; Claman, D.; Huntley, T.; Park, S.; Campbell, M.; Palme, C.; Iber, C.; Eastwood, Peter; Hillman, D.; Barnes, M. (2014)
      Reduced upper airway muscle activity during sleep is a key contributor to obstructive sleep apnea pathogenesis. Hypoglossal nerve stimulation activates upper airway dilator muscles, including the genioglossus, and has the ...
    • Laboratory and home comparison of wrist-activity monitors and polysomnography in middle-aged adults
      Dunican, I.; Murray, K.; Slater, J.; Maddison, K.; Jones, M.; Dawson, B.; Straker, Leon; Caldwell, J.; Halson, S.; Eastwood, P. (2018)
      © 2017, Japanese Society of Sleep Research. Accurate measurement of time at lights out is essential for calculation of several measures of sleep in wrist-activity monitors. While some devices use subjective reporting of ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.