Show simple item record

dc.contributor.authorLiu, Jian
dc.contributor.authorBo, X.
dc.contributor.authorZhao, Z.
dc.contributor.authorGuo, L.
dc.date.accessioned2018-12-13T09:08:02Z
dc.date.available2018-12-13T09:08:02Z
dc.date.created2018-12-12T02:46:47Z
dc.date.issued2015
dc.identifier.citationLiu, J. and Bo, X. and Zhao, Z. and Guo, L. 2015. Highly exposed Pt nanoparticles supported on porous graphene for electrochemical detection of hydrogen peroxide in living cells. Biosensors and Bioelectronics. 74: pp. 71-77.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/70874
dc.identifier.doi10.1016/j.bios.2015.06.042
dc.description.abstract

© 2015 Elsevier B.V. In this study, we developed a novel biosensor based on highly exposed Pt nanoparticles (Pt NPs) decorated porous graphene (PG) for the reliable detection of extracellular hydrogen peroxide (H<inf>2</inf>O<inf>2</inf>) released from living cells. The commercially available low-cost hydrophilic CaCO<inf>3</inf> spheres were used as template for preparing PG. The porous structure provided larger surface area and more active sites. Due to the porous structure of PG, the Pt NPs supported on PG were not secluded by aggregated graphene layers and were highly exposed to target molecules. Ultrafine Pt NPs were well dispersed and loaded on PG by a method of microwave assistance. Electrochemical performances of the Pt/PG nanocomposites modified glassy carbon electrode (GCE) were investigated. The electrocatalytic reduction of H<inf>2</inf>O<inf>2</inf> showed a wide linear range from 1 to 1477µM, with a high sensitivity of 341.14µAmM<sup>-1</sup>cm<sup>-2</sup> and a limit of detection (LOD) as low as 0.50µM. Moreover, the Pt/PG/GCE exhibited excellent anti-interference property, reproducibility and long-term storage stability. Because of these remarkable analytical advantages, the constructed sensor was used to determine H<inf>2</inf>O<inf>2</inf> released from living cells with satisfactory results. The superior catalytic activity makes Pt/PG nanocomposites a promising candidate for electrochemical sensors and biosensors design.

dc.publisherElsevier BV
dc.titleHighly exposed Pt nanoparticles supported on porous graphene for electrochemical detection of hydrogen peroxide in living cells
dc.typeJournal Article
dcterms.source.volume74
dcterms.source.startPage71
dcterms.source.endPage77
dcterms.source.issn0956-5663
dcterms.source.titleBiosensors and Bioelectronics
curtin.departmentWASM: Minerals, Energy and Chemical Engineering (WASM-MECE)
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record