Curtin University Homepage
  • Library
  • Help
    • Admin

    espace - Curtin’s institutional repository

    JavaScript is disabled for your browser. Some features of this site may not work without it.
    View Item 
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item

    Investigation on architectures for power system communications between substations using IEC 61850

    Access Status
    Fulltext not available
    Authors
    Das, Narottam
    Modi, H.
    Islam, Syed
    Date
    2014
    Type
    Conference Paper
    
    Metadata
    Show full item record
    Citation
    Das, N. and Modi, H. and Islam, S. 2014. Investigation on architectures for power system communications between substations using IEC 61850, in Abu-Siada, A. and Masoum, M. (ed), Proceedings of the 2014 Australasian Universities Power Engineering Conference, Sep 28-Oct 1 2014, pp. 1-6. Bentley, WA: Institute of Electrical and Electronics Engineers.
    Source Title
    2014 Australasian Universities Power Engineering Conference, AUPEC 2014 - Proceedings
    DOI
    10.1109/AUPEC.2014.6966480
    ISBN
    9780646923758
    School
    Department of Electrical and Computer Engineering
    URI
    http://hdl.handle.net/20.500.11937/8064
    Collection
    • Curtin Research Publications
    Abstract

    © 2014 ACPE. This paper investigates the communication network architectures for power systems between substations using IEC 61850. Optimized Network Engineering Tools (OPNET) is used for the simulations. The simulation results show the performance of individual architectures power system communications (PSC) for substation automation systems (SASs). Nowadays, interoperability among multi-vendor substations automation devices is achievable using IEC 61850 standard which allows the PSC between substations. Ethernet based communication protocols for the SASs are specified in IEC 61850 standard. These standards include Ethernet based process-level connections between switchyards and control rooms. However, their in-service performance is not well known yet. The IEC 61850 demands for a communication topology which is zero point failure proof and provides worthy data transmission rates, without pursuing any delays. In order to achieve these norms, Ethernet architectures are modeled and analyzed in detail. The performance of individual architecture also analyzed in terms of their reliability, availability and efficiency of data transfer. The hybrid, star-ring and redundant ring network architectures are the most efficient in terms of data transmission, delay times, reliability and availability between the SASs for data transmission.

    Related items

    Showing items related by title, author, creator and subject.

    • Analysis of power system communication architectures between substations using IEC 61850
      Das, N.; Islam, Syed (2014)
      Interoperability among multi-vendor substations automation devices, is now achievable due to the introduction of IEC 61850 standard, which allows power system communication between substations. This standard does not ...
    • Performance evaluation of data transmission in a single and double bus network within the utility substation based on IEC 61850
      Kumar, S.; Das, N.; Muigai, J.; Islam, Syed (2014)
      © 2014 IEEE. Communication between intelligent electronic devices (IED's) is an important feature of a utility substation automation system based on IEC 61850. Time critical information related to fault and overcurrent, ...
    • Modelling and analysis of IEC 61850 for end-to-end delay characteristics with various packet sizes in modern power substation systems
      Wong, T.; Das, Narottam (2014)
      Substation is an important part of electricity generation, transmission and distribution system, where voltage is stepped up and down or vice versa. The substation serves as a centre point of all kind of connection between ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.