Show simple item record

dc.contributor.authorFu, X.
dc.contributor.authorSale, M.
dc.contributor.authorDing, B.
dc.contributor.authorLewis, W.
dc.contributor.authorSilvester-Dean, Debbie
dc.contributor.authorLing, C.D.
dc.contributor.authorD'Alessandro, D.M.
dc.date.accessioned2023-05-01T03:51:35Z
dc.date.available2023-05-01T03:51:35Z
dc.date.issued2022
dc.identifier.citationFu, X. and Sale, M. and Ding, B. and Lewis, W. and Silvester, D.S. and Ling, C.D. and D'Alessandro, D.M. 2022. Hydrogen-bonding 2D coordination polymer for enzyme-free electrochemical glucose sensing. CrystEngComm. 24 (25): pp. 4599-4610.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/91823
dc.identifier.doi10.1039/d2ce00240j
dc.description.abstract

Regular detection of blood glucose levels is a critical indicator for effective diabetes management. Owing to the intrinsic highly sensitive nature of enzymes, the performance of enzymatic glucose sensors is typically impacted by unwanted dependencies on pH, temperature and humidity. Correspondingly, the development of robust enzyme-free glucose sensors is desired due to their potential to improve upon the operational flexibility of traditional systems. In this study, a new coordination polymer (CP) incorporating melamine (Mel), biphenyl-4,4′-dicarboxylate (BPDC2−) co-ligands and Zn(ii) metal nodes, [Zn2(BPDC)1Mel0.5-Mel0.5]·(DMF0.6) {denoted CP1}, was synthesised and characterized for non-enzymatic glucose sensing. Here, the 2D layers are connected by hydrogen bond (H-bond) interactions between the interstitial melamine molecules. In addition to conventional characterization methods, we also used density functional theory (DFT) calculations and variable temperature Raman spectroscopy to computationally and experimentally explore the H-bond interactions in CP1. CP1 was deposited onto a glassy carbon (GC) electrode to facilitate its incorporation into an electrochemical sensing device. When used as an electrochemical glucose sensor, the CP1/GC electrode exhibited accurate clinical performance characteristics, with a wide linear sensing range extending from 5.6 μM to 5.56 mM (R2 = 0.9852) and with a high sensitivity of 517.36 μA mM−1 cm−2. Low sample loadings are a further important advantage associated with this CP-based non-enzymatic glucose sensor.

dc.languageEnglish
dc.publisherROYAL SOC CHEMISTRY
dc.subjectScience & Technology
dc.subjectPhysical Sciences
dc.subjectChemistry, Multidisciplinary
dc.subjectCrystallography
dc.subjectChemistry
dc.subjectINITIO MOLECULAR-DYNAMICS
dc.subjectTOTAL-ENERGY CALCULATIONS
dc.subjectMETAL-ORGANIC FRAMEWORKS
dc.subjectSENSITIVE DETECTION
dc.subjectRESPONSIVE INSULIN
dc.subjectCHEMICAL FIXATION
dc.subjectFACILE SYNTHESIS
dc.subjectNANOPARTICLES
dc.subjectCOMPOSITE
dc.subjectOXIDASE
dc.titleHydrogen-bonding 2D coordination polymer for enzyme-free electrochemical glucose sensing
dc.typeJournal Article
dcterms.source.volume24
dcterms.source.number25
dcterms.source.startPage4599
dcterms.source.endPage4610
dcterms.source.titleCrystEngComm
dc.date.updated2023-05-01T03:51:26Z
curtin.departmentSchool of Molecular and Life Sciences (MLS)
curtin.accessStatusOpen access
curtin.facultyFaculty of Science and Engineering
curtin.contributor.orcidSilvester-Dean, Debbie [0000-0002-7678-7482]
curtin.contributor.researcheridSilvester-Dean, Debbie [D-4679-2013]
dcterms.source.eissn1466-8033
curtin.contributor.scopusauthoridSilvester-Dean, Debbie [14623139100]
curtin.repositoryagreementV3


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record