Show simple item record

dc.contributor.authorWang, K.
dc.contributor.authorWu, Jianping
dc.contributor.authorKirk, Thomas
dc.date.accessioned2017-01-30T11:22:06Z
dc.date.available2017-01-30T11:22:06Z
dc.date.created2014-03-24T20:00:47Z
dc.date.issued2013
dc.identifier.citationWang, Kuyu and Wu, Jianping and Kirk, Thomas. 2013. Depth-dependent refractive index of normal and early degenerated articular cartilage. Journal of Biomedical Optics. 18 (10): 105003 (8 pp.).
dc.identifier.urihttp://hdl.handle.net/20.500.11937/10969
dc.identifier.doi10.1117/1.JBO.18.10.105003
dc.description.abstract

The depth distributions of refractive index (RI) in normal and early degenerated articular cartilage (AC) were measured and correlated to the pathological statuses. Utilizing a confocal microscope, the depth distribution of RI was determined with an interval of 50µm from the articular surface and approximated as a smooth curve. The fluctuation of RI was quantified with a specially defined coefficient and the proteoglycan (PG) loss was quantified with histological images. The overall RI of the AC collected from the femoral condyles of mature sheep was 1.4444. Significant differences existed in the refractive indices of different cartilage samples or even in the different depths of the same sample. The RI of normal cartilage distributed as a regular ramp or arch curve with depth and peaked in the middle-deep zone. The cartilage samples detected with high PG losses were coupled with severe fluctuations of RI. The fluctuating level was increased with pathological progress. The coefficient of RI fluctuation can distinguish the normal cartilage from the initially degenerated one, which potentially provides an indicator to detect the pathological development of AC.

dc.publisherSPIE
dc.subjectarticular cartilage confocal microscopy depth-dependent property proteoglycan loss refractive index distribution
dc.titleDepth-dependent refractive index of normal and early degenerated articular cartilage
dc.typeJournal Article
dcterms.source.volume18
dcterms.source.number10
dcterms.source.startPage105003
dcterms.source.endPage1
dcterms.source.issn1083-3668
dcterms.source.titleJournal of Biomedical Optics
curtin.note

This article is published under the Open Access publishing model and distributed under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/3.0/ Please refer to the licence to obtain terms for any further reuse or distribution of this work.

curtin.department
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record