Show simple item record

dc.contributor.authorBusetti, Francesco
dc.contributor.authorLinge, Kathryn
dc.contributor.authorBlythe, Justin
dc.contributor.authorHeitz, Anna
dc.date.accessioned2017-01-30T12:46:20Z
dc.date.available2017-01-30T12:46:20Z
dc.date.created2008-11-25T06:21:22Z
dc.date.issued2008
dc.identifier.citationBusetti, Francesco and Linge, Kathryn and Blythe, Justin and Heitz, Anna. 2008. Rapid analysis of iodinated X-ray contrast media in secondary and tertiary treated wastewater by direct injection liquid chromatography-tandem mass spectrometry. Journal of Chromatography A 1213 (2): pp. 200-208.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/25024
dc.identifier.doi10.1016/j.chroma.2008.10.021
dc.description.abstract

The iodinated x-ray contrast media (ICM) are the most widely administered intravascular pharmaceuticals and are known to persist in the aquatic environment. A rapid method using direct injection liquid chromatography-tandem mass spectrometry (DI-LC-MS/MS) has been developed to measure eight ICM. These include iopamidol, iothalamic acid, diatrizoic acid, iohexol, iomeprol, iopromide, plus both ioxaglic acid and iodipamide, which have not previously reported in the literature. The LC-MS/MS fragmentation patterns obtained for each of the compounds are discussed and the fragments lost for each transition are identified. Matrix effects in post-RO water, MQ water, tap water and secondary effluent have also been investigated. The DI-LC-MS/MS method was validated on both secondary and tertiary treated wastewater, and applied to samples from an advanced activated sludge wastewater treatment plant (WWTP) and a water recycling facility using microfiltration (MF) and reverse osmosis (RO) in Perth, Western Australia. As well as providing information of the efficacy for RO to remove specific ICM, these results also represent the first values of ICM published in the literature for Australia.

dc.publisherElsevier
dc.subjectiodinated x-ray contrast media (ICM)
dc.subjectLC-MS
dc.subjectwastewater
dc.subjectwater reuse
dc.subjectdirect injection
dc.subjectreverse osmosis
dc.titleRapid analysis of iodinated X-ray contrast media in secondary and tertiary treated wastewater by direct injection liquid chromatography-tandem mass spectrometry
dc.typeJournal Article
dcterms.source.volume1213
dcterms.source.number2
dcterms.source.startPage200
dcterms.source.endPage208
dcterms.source.issn00219673
dcterms.source.titleJournal of Chromatography A
curtin.note

Copyright © 2008 Elsevier B.V. All rights reserved.

curtin.departmentDepartment of Applied Chemistry
curtin.accessStatusOpen access
curtin.facultyDepartment of Applied Science
curtin.facultyFaculty of Science and Engineering


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record