Optimization of Computed Tomography Angiography Protocols for Follow-Up Type B Aortic Dissection Patients by Using 3D Printed Model
Citation
Source Title
ISSN
Faculty
School
Remarks
© 2021 The Authors. Published by MDPI Publishing.
Collection
Abstract
Thoracic endovascular aortic repair (TEVAR) is a life-saving therapy for type B aortic dissection (TBAD). However, surveillance computed tomography (CT) scans in post-TEVAR patients are associated with high radiation dose, thus resulting in potential risk of radiation-induced malignancy. In this study, we developed a patient-specific three-dimensional (3D) printed phantom with stent grafts in situ, then scanned the phantom with different CT protocols to determine the optimal scanning parameters for post-treatment patients. The CT scans were conducted with different kVp and pitch values (80, 100, 120 kVp and pitch of 1.2, 1.5, 2.0, 2.5), resulting in a total of 12 datasets. Signal-to-noise ratio (SNR) was measured to determine and compare the image quality between different datasets. Results showed no significant differences in SNR between different kVp when the pitch value was 1.2. At low pitch values, a decrease in kVp from 120 to 80 led to a significant effective dose reduction by more than 20%. SNR decreased by 30% when pitch was increased from 1.2 to 2.5 at 80 kVp, and 20% at 120 kVp. In contrast, there was only a 3.9% decrease in SNR when kVp was reduced from 120 to 80 at pitch 1.2, and 15.9% at pitch 2.5. High pitch with 100 kVp can effectively reduce the dose while maintaining image quality.
Related items
Showing items related by title, author, creator and subject.
-
Aldosari, S.; Jansen, S.; Sun, Zhonghua (2018)Background: Three-dimensional (3D) printing has been shown to accurately replicate anatomical structures and pathologies in complex cardiovascular disease. Application of 3D printed models to simulate pulmonary arteries ...
-
Aldosari, S.; Jansen, S.; Sun, Zhonghua (2019)Background: Computed tomography pulmonary angiography (CTPA) is the preferred imaging modality for diagnosis of patients with suspected pulmonary embolism (PE). Radiation dose associated with CTPA has been significantly ...
-
McCann, K.; Lim, V.; Tomlinson, G.; Way, J.; Alshamakhi, A.; Ong, J.; Sun, Zhonghua (2007)We aimed to investigate relationship of radiation dose and image quality in 3D multi-detector CT angiography of abdominal aortic aneurysm based on an aorta phantom. The study was conducted using a human aorta phantom ...